Description
- The Smart BatteryProtect disconnects the battery from non-essential loads before it is completely discharged (which would damage the battery) or before it has insufficient power left to crank the engine. When using Bluetooth to program the Smart BatteryProtect any required engage/disengage levels can be set. Alternatively, one of nine predefined engage/disengage levels can be set with the programming pin (see manual). If required, Bluetooth can be disabled.
- A special setting for Li-ion batteries In this mode the BatteryProtect can be controlled by the VE.Bus BMS. Note: the BatteryProtect can also be used as a charge interrupter in between a battery charger and a Li-ion battery. See connection diagram in the manual. Ultra-low current consumption This is important in case of Li-ion batteries, especially after low voltage shutdown. Please see our Li-ion battery datasheet and the VE.Bus BMS manual for more information.
- Over voltage protection To prevent damage to sensitive loads due to over voltage, the load is disconnected whenever the DC voltage exceeds 16.3V respectively 32.6V. Ignition proof No relays but MOSFET switches, and therefore no sparks.
- Delayed alarm output The alarm output is activated if the battery voltage drops below the preset disconnect level during more than 12 seconds. Starting the engine will therefore not activate the alarm. The alarm output is a short circuit proof open collector output to the negative (minus) rail, max. current 50 mA. The alarm output is typically used to activate a buzzer, LED or relay.
- Delayed load disconnect and delayed reconnect The load will be disconnected 90 seconds after the battery voltage drops below the preset level. If the battery voltage increases again to the connect threshold within this time period (after the engine has been started for example), the load will not be disconnected. The load will be reconnected 30 seconds after the battery voltage has increased to more than the preset reconnect voltage.
- ›See more product details
Size Name:220A Smart
Technical Specification Smart BatteryProtect Smart BP-220 Maximum continuous load current* 220A Peak current (during 30 seconds) 600A Operating voltage range 6 –35V Current consumption BLE On When on: 1,4 mA When off or low voltage shutdown: 0,9 mA BLE Off When on: 1,2 mA When off or low voltage shutdown: 0,7 mA Alarm output delay 12 seconds Maximum load on alarm output 50 mA (short circuit proof) Load disconnect delay 90 seconds (immediate if triggered by the VE.Bus BMS) Load reconnect delay 30 seconds Default thresholds Disengage: 10,5V or 21V Engage: 12V or 24V Operating temperature range Full load: -40°C to +40°C (up to 60% of nominal load at 50°C) IP rating Electronics: IP67 (potted) Connections: IP00 Connection M8 Weight 0,8 kg Dimensions (hxwxd) 63 x 123 x 120 mm * The BatteryProtect is not designed for reverse currents from charging sources